All wiring diagrams are available for all RV AC units. Need more help? SoftStart will work with you on the phone during installation if necessary. Installation is easy and most can perform the install with no assistance.

Save my name, email, and website in this browser for the next time I comment. Home » Air Conditioners » Top 10 Best soft start kit for air conditioner Reviews We may earn a small part of the sale from links to any products or services on this site. With our new technology, SoftStartRV allows your rooftop air conditioner, refrigerator, heater, micro wave, hair dryer, fan, and TV to start, even with low power.

A full catalog of articles, web installation guides, live rooftop support via phone, and much more, to make things as easy as possible. Bestseller No. See real, time before and after results Pull into an RV park with low voltage or dangerous electrical EasyStart also monitors power quality and protects your acs compressor from damage.

The GS11 is the big brother of the GS It features heavier gauge conductors inside and out, but otherwise functions the exact same.

Adding a soft start function to your power tools, pumps, etc. And the best part, it's so simple and versatile that you can soft start your other compatible equipment as well. You can even leave multiple devices plugged into the soft starter at all times via a splitter or power strip. Just remember, only use one device at a time and make sure that the GS10 or GS11 maximum current rating is not exceeded by your equipment.

Originally built for use with universal motor power tools, this soft starter has since evolved to provide you so much more with a wide-variety of applications:. Some limitations apply. The information in this list does not guarantee compatibility with your device. Any device not listed in this chart may not function with this soft starter. If unsure, please contact us before purchasing info raymondinnovations.

We live off-grid, on our 40 foot sailboat currently in the Florida Keys. Our floating home is self-sufficient with solar panels, lithium iron phosphate batteries, an electric motor, reverse osmosis desalination watermaker and all of the comforts of most homes - even a washing machine. We needed to be able to operate our watermaker, which includes a 1hp motor.

Startup, with the watermaker connected to the inverter, would trip the breaker on our distribution panel, requiring us to power the process with a portable generator, until we learned about the GS11 Soft Starter. Let me tell you - we are able to run the watermaker, using our lithium batter bank, as though we were connected to shore power. No glitches, no hiccups, no issues at all. The GS11 is super simple to use. You just plug it into the three-pronged outlet and then plug in your appliance to the GS The circuit will limit the current through the supply wires to 5.

After that time the relay will close and the current flow won't be restricted anymore. This is a very interesting circuit if you have a large toroid with big electrolytic caps connected to the power supply, since these will act like short circuits for a small amount of time if they start charging.

This unit is a delay unit that can be connected directly to the mains power supply. This unit has a delay circuit and for the delayed time the mains power is supplied through power resistors minimizing in this way the big inrush current due to big capacitors and big toroidal transformers in the power supply.

When everything is stable it shorts the power resistors and supplies the mains power directly. All Rights Reserved.